iec标准
根据国家安全法的规定-台球系统
2023年3月17日发(作者:上清所)62271-203@IEC:2003
CommonnumberingofIEC62271publicationsfallingundertheresponsibility
ofsubcommitteesSC17AandSC.17c
IEC62271
series
HIGH-VOLTAGESWITCHGEARANDCONTROLGER
高压开关设备和控制设备
OldIECnumber
ifany
partNewtitle
1Commonspecifications
通用说明
IEC60694
2Seismicqualificationforratedvoltagesof72.5Kvandabove
72.5kV及以上设备抗地震性能
-
100High-voltagealternatingcurrentcircuit-breakers
高压交流断路器
IEC60056
101Synthetictesting
合成测试
IEC60427
102High-voltagealternatingcurrentdisconnectionsandearthingswitches
高压交流隔离开关和接地开关
IEC60129
103Switchesforratedvoltagesabove1kVandlessthan52kV
1kV~52kV的开关设备
IEC60265-1
104Switchesforratedvoltagesof52kVandabove
52kV及以上的高压开关设备
IEC60265-2
105Alternatingcurrentswitch-fusecombinations
高压交流开关-熔断器组合
IEC60420
106Alternatingcurrentcontactorsandcontactor-basedmotor-starters
交流接触器和
IEC60470
107Alternatingcurrentswitchgear-fusecombinations
高压交流开关设备-熔断器组合
-
108Switchgearhavingcombinedfunction
开关设备的联动功能
-
109Seriescapacitorby-passswitches
串连电容器
-
200ACmetal-enclosedswitchgearandcontrolgearforratedvoltageabove
1kVanduptoandincluding52kV
1kV~52kV交流金属封闭开关和控制设备
IEC60298
201Insulation-enclosedswitchgearandcontrolgearforratedvoltageupto
andincluding52kV
52kV及以上绝缘封闭开关设备
IEC60466
202High-voltage/Low-voltageprefabricatedsubstations
高低压箱式变电站
IEC61330
203Gas-insulatedmetal-enclosedswitchgearforratedvoltagesabove52kV
额定电压在52kV以上气体绝缘金属封闭开关设备
IEC60517
204High-voltagegas-insulatedtransmissionlinesforratedvoltagesof72.5
kVandabove
额定电压在72.5kV及以上高压气体绝缘输电线路
IEC61640
(300)Guideforseismicqualificationofhigh-voltagealternatingcurrent
circuit-breakers
高压交流断路器地震条件导则
IEC61166
(301)Guideforinductiveloadswitching感应负载开关导则(高压交流断路
器)
IEC61223
(302)Guideforshort-circuitandswitchingtestproceduresformetal-enclosed
anddeadtankcircuit-breakers
金属封闭和落地罐式断路器的短路和开合试验程序导则
IEC61633
(303)Useandhandlingofsulphurhexafluoride(SF6)inhigh-voltage
switchgearandcontrolgear
高压开关和控制设备种SF6的使用和操作
IEC61634
(304)Additionalrequirementsforenclosedswitchgearandcontrolgearfrom1
kVto72.5kVtobeusedinseversclimaticconditions
1kV到72.5kV封闭开关和控制设备用在特殊环境条件下的附加
要求
IEC60932
(305)Cableconnectionsforgas-insulatedmetal-enclosedswitchgearforrated
voltagesabove52kV.
52kV及以上气体绝缘金属封闭开关设备的电缆连接
IEC60859
(306)Directconnectionbetweenpowertransformersandgas-insulated
metal-enclosedswitchgearforratedvoltagesabove52kV.
52kV及以上发电机变压器和气体绝缘金属封闭开关设备的直接连
接
IEC61639
(307Useofelectronicandassociatedtechnologiesinauxiliaryequipmentof
switchgearandcontrolgear
开关设备和控制设备的辅助设备种电气和相关技术的使用
IEC62063
(308)Guideforasymmetricalshort-circuitbreakingtestdutyT100a
非对称短路开端试验导则
-
(309)TRVparametersforhigh-voltageswitchgearandcontrolgearforrated
voltagesabovelkVandlessthan100kV.
-
(310)Electricalendurancetestingforcircuit-breakersrated72.5kVandabove
72.5kV及以上的断路器的电动力续性试验
-
62271-2003◎IEC:2003
Table102-Preferredratedinsulationlevelsforratedvoltages
forequipmentofrange1
Ratedvoltagefor
equipment
Ur
kV()
设备额定电压
Ratedshort-duration
power-frequencywithstandvoltage
(额定短时工频耐受电压)
Ud
kV()
Ratedlightningimpulsewithstand
voltage
(额定雷电冲击耐受电压)
Up
kV(peckvalue)
Phase-to-earth,
acrossopen
Acrossthe
isolatingdistance
Phase-to-earth,
acrossopen
Acrossthe
isolatingdistance
switchingdevice
andbetween
phase
相对地,相间和
通过断开的设备
通过的绝缘距离switchingdevice
andbetween
phase
相对地,相间和
通过断开的设备
通过的绝缘距离
(1)(2)(3)(4)(5)
72.514
120
12323
0750
170
24546
NOTEValuesincolumn(2)areapplicable
A)Fortypetests,phase-to-earthandbetweenphases;
B)Forroutinetests,phase-to-phase,andacrosstheopenswitchingdevice.
Valuesincolumns(3),(4)and(5)areapplicablefortypetestsonly.
注意:第二列的电压用于:
(1)相对地和相间的测试类型
(2)第三、四、五列种的电压值仅适用于相对地,相间和通过断开的开关设备的常规测
试,
62271-2003◎IEC:2003
Table103-Preferredratedinsulationlevelsforratedvoltages
forequipmentofrangeII
Ratedvoltagefor
equipment
Ur
kV()
设备额定电压
Ratedshort-duration
power-frequencywithstandvoltage
(额定短时工频耐受电压)
Ud
kV()
Ratedswitchingimpulsewithstandvoltage
(额定开关冲击耐受电压)
Us
kV()
Ratedlightningimpulsewithstand
voltage
(额定雷电冲击耐受电压)
Up
kV(peckvalue)
Phase-to-earth,
andbetween
phase(note3)
相对地和相间
acrossopen
switchingdevice
and/orisolating
distance
(note3)
Phase-to-earth,
andacrossopen
switchingdevice
相对地和相间
betweenphase
(note4)
相间
Acrossisolating
distance(note1,2
and3)
通过绝缘距离
Phase-to-earth,
andbetween
phase
相对地和相间
acrossopen
switchingdevice
and/orisolating
distance
(note3)
通过断开的开关设
备和/或绝缘距离
(1)(2)(3)(4)(5)(6)(7)(8)
3275700(+245)10501050(+170)
3625200(+295)11751175(+205)
42575900(+345)14251425(+240)
55760900(+450)15501550(+315)
8524201100(+650)21002100(+453)
NOTE1column(6)isalsoapplicabletosomecircuit-breakers,seeIEC62271-100.
NOTE2incolumn(6),valuesinbracketsarethepeckvaluesofthepower-frequencyvoltageUr/√2/√3appliedtotheoppositeterminal(combinedvoltage)
Incolumn(8),valueinbracketsarethepeckvaluesofthepower-frequencyvoltage0.7Ur/√2/√3appliedtotheoppositeterminal(combinedvoltage).see
annexDofIEC60694.
NOTE(3)Valuesincolumn(2)areapplicable:
(a)fortypetests,phase-to-earthandbetweenphases;
(b)forroutinetests,phase-to-earth,phase-to-phase,andacrosstheopenswitchingdevice.
Valuesincolumns(3),(4),(5),(6),(7)and(8)areapplicablefortypetestsonly.
NOTE(4)thesevaluesarederivedusingthemultiplyingfactorsstatedinTable3ofIEC60070-1(1993)
注1:第6列也适用于一些断路器,参见IEC62271-100.
注2:在第6列,括号内的数字是加在同一极相应端子上的反极性工频电压的峰值。
注3:第二列种的数字适用于:
相间试验类型
相对地,相间和通过断开的开关设备间的常规测试
(3),(4),(5),(6),(7)和(8)列种的数值仅用于典型测试
注4: